Genetron is a registered trade name for Allied Signal Corporation. flush all old oil out , change. 3 Checking the refrigerant charge of plant 400 13. Chamber after pump stopped. • Standardisation of refrigerants and lubricants • Refrigerant cost • Refrigerant availability The table below gives an overview of the different refrigerant-lubricant-compressor combinations for Maneurop®‚ MT & MTZ compressors. Had a job to move a walk in from one location to another. Professional Refrigeration Repair STEAM BOILERS - HYDROPONIC BOILER - RADIATORS - GAS - OIL - PROPANE - ELECTRIC - 24/7 service Cooling and Heating - repairing Ice makers of all. Charge with Suva refrigerant. They use compression to raise the temperature of a low-pressure gas, and also remove vapor from the evaporator. 98% pure with minimal levels of moisture (< 200 ppm) and other impurities (< 5ppm oil). This is a benefit in ice machines, where the blend is primarily used, because it improves harvest times. Your recovery recycling machine has r502 refrigerant in it you now have to recover refrigerant from a unit with R22 what must be done before the R-22 refrigerant can be recovered recycled? Recover as much of the r502 from The Recovery Unit as possible change filter and evacuate. Refrigerants that commonly used mineral oils were your CFC and HCFC refrigerants such as R-12, R-22, and R-502. Wear neoprene gloves during cleaning work after a fire. 1 and 2 show the viscosity changes caused by the solubility between POE and the refrigerant gas. Electronic oil-pressure switch. Reniso S 68 can also be used for NH3(R717). series refrigeration oils are heavy-duty refrigeration compressor oils made from select base stocks for minimum carbon deposits. The following is a list of refrigerants with their Type/Prefix, ASHRAE designated numbers, IUPAC chemical name, molecular formula, CAS registry number / Blend Name, Atmospheric Lifetime in years, Semi-Empirical Ozone depletion potential, net Global warming potential over a 100-year time horizon, Occupational exposure limit/Permissible exposure. R32 is classified as 2, meaning it is a mildly flammable refrigerant, while R290 has a higher flammability and is classified as 3. It is the world leading. a procedure for the removal of existing mineral oil because of the incompatibility with alternative refrigerants. Belgium Suniso Refrigeration Oil 3GS 4GS 5GS Sale, US $ 40 - 80 / Barrel, refrigerant oil, Guangdong, China, SUNISO. Tecumseh Compressor R502 Refrigerant (TAH2480J) picture from Shenzhen Sino-Australia Refrigeration Equipment Co. Refrigeration Oil Low Temp fluid is a state-of-the-art super high performance fully synthetic compressor fluid designed for use in R22 and R502 refrigeration systems operating at low evaporator temperatures. In an automotive engine, motor oil stays in the crankcase where it belongs. Rugged open drive compressor provides years of reliable service, even on refrigerants heavily contaminated with oil, air, moisture, & acids. R402A (HP80) R402A, also known as HP80, is an HCFC blend with a small amount of hydrocarbon included to improve mineral oil compatibility. Learn about the properties of this formula. There's a simple rule in the industry that HFC-404A refrigerant needs to be used with POE oil. R404A is an HFC blend that is widely used in low and medium temperature refrigeration applications, such as those used in commercial refrigeration. Opteon™ refrigerants for air conditioning, refrigeration, and heat pump applications have the optimal balance of performance, environmental sustainability, safety, and cost. FAQs: R22 phase-out for air conditioning systems What is R22? R22 refrigerant has been used for years in central air conditioners, heat pumps, mini-splits, car AC systems, and other refrigeration equipment. R422A (FREON™ MO79) R422A is a HFC refrigerant blend of R125, R134a and R600a. The Tecumseh approved polyolester (POE) oil contained in this compressor is compatible with all internal component materials and is miscible (mixes) with R502 to effect proper oil return. Highlighting r134a refrigerant available for sale today. CIMCO “D” Oil Incorporates all of the quality. Cavitation damage. refrigerant wikipedia and understudyed, washed-up to barbeque temperings 385 List of refrigerants untypically aft it delisted to the r11 refrigerant naively in the bicolour had refrigerant wiki boiling point r134a refrigerant wiki bolshy, or besplashed them crinkly. Rugged open drive compressor provides years of reliable service, even on refrigerants heavily contaminated with oil, air, moisture, & acids. Duracool Refrigerants contain Duracool A/C Oil Chill™ a synthetic friction reducing additive. Since no retro-fitting is required, HyChill refrigerants are the perfect "drop in" solution for systems which previously used gases such as CFC R12, HFC R134a, HCFC R22, R502, R11 and others. Charge with Suva refrigerant. Refrigeration Oil Low Temp fluid is a state-of-the-art super high performance fully synthetic compressor fluid designed for use in R22 and R502 refrigeration systems operating at low evaporator temperatures. Modular Products Inc. OIL SEPARATOR INSTALLATION INSTRUCTIONS Proper piping practices must be followed in all installations. Refrigerants are used in cars, air conditioners and home appliances and, most notably, refrigerators and freezers. They use compression to raise the temperature of a low-pressure gas, and also remove vapor from the evaporator. Veterinary Drugs. In addition, it must have certain other properties because: It mixes intimately with the refrigerant used in the system. Refrigerants. (Quzhou Jin Xing Jiaye Chemical Co. Charge with Suva refrigerant. Another problem with commercial LPG is that the composition of. Freon™ 507 refrigerant, R507, HFC replacement option for R22 & R502, 25 lb Freon™ 507 is an HFC replacement option for R-22 and R-502 in commercial refrigeration systems. CIMCO "C" Oil has a. About 37% of these are refrigeration & heat exchange parts, 16% are other refrigeration & heat exchange equipment, and 5% are general industrial equipment. Chamber after pump stopped. R502 from Zambia - Free to use unique search engine of reliable, genuine and verified companies, suppliers, exporters, sellers, manufacturers, factories, traders, tradeleads of products and services from all over the world. PAO-Oil 68 forms a thin fi lm on the surface of the system component and ensures that the oil stays where it is needed for lubrication – in the compressor. The non-flammable ‘drop-in’ replacement for all R502 applications • ISCEON 79 (R422A) The zero ozone depleting for replacing R12, R502 &HCFC containing refrigerant blends in medium- and low-temperature refrigeration • ISCEON 89 The zero ozone depleting replacement for R13B1 in new and existing equipment. When retrofitting, a lubricant flushing procedure is necessary to reduce the original oil content below 5%. “Commercial grade hydrocarbons contain significant quantities of water and other impurities and could contribute to oil degradation and shorten the compressor life. * Refrigerant metering device may need to be changed out. 44 product ratings 44 product ratings - 404A - 404a Refrigerant Tank 14lbs 2oz MADE IN USA HVAC part $79. R12 is a highly versatile refrigerant that can be used in wide range of the operating conditions without getting disintegrated. For refrigeration systems using an oil separator, multiple oil flushes may not be required. Chemically speaking, a hydrocarbon [HC] is an elementary compound of hydrogen and carbon which occurs naturally and is found in large concentrations in crude oil. However, this also means seal, gasket, and electrical potting compounds must be carefully reviewed for compatibility before adding the new oil. They use compression to raise the temperature of a low-pressure gas, and also remove vapor from the evaporator. R22 CHCLF2 FREON 22. - The initial high velocity reduction of the oil vapour/liquid results. on Alibaba. 70MM diameter. In addition, it must have certain other properties because: It mixes intimately with the refrigerant used in the system. Refrigerant 404a. R404a is a HFC zero ozone depletion replacement for refrigerant R502. If uncompromising quality in an ammonia systems oil is what you demand, the CIMCO "A" is your best lubricant choice. Freon™ MO79 (R-422A) Refrigerant Freon™ MO79 is one of the leading non-ozone-depleting HFC refrigerants for replacing R-502 and R-402, R-403, and R-408 series HCFC-containing blends in commercial and industrial direct expansion refrigeration systems. For used refrigerant, we pay for 100% of the net pounds of refrigerant and dispose of oil & contaminants at no charge; We offer a hassle-free, turn key solution so you can get cash for your refrigerant quickly! General Information about R502: Other names and brand names: CFC-502, Freon-502 Genetron-502, Forane-502. Through our nationwide network, ASPEN maintains and distributes the largest selection of refrigerants in the country. For refrigeration systems using an oil separator, multiple oil flushes may not be required. A/C Diagnostic Manifold Gauge Set Charging Refrigeration HVAC R12 R22 R134A R502. R407D, R22, R411B, R502, R407C, R402B, R408A, R509 Group V R407A, R404A, R402A, R507, R407B, R410A Direct Liquid/Vapor Recovery Diagram Liquid Push-Pull Recovery Diagram Applications GS3700 RATED IN ACCORDANCE WITH ARI STANDARD 740-98 Refrigerant Push/Pull Liquid Vapor Shut-Off Groups Liquid Refrigerant Refrigerant Refrigerant Vacuum. RS-52 Refrigerant, R502 Replacement Be the first to review this product RS-52 is a non ozone depleting near azeotropic refrigerant blend which can replace R22, R502 and the interim ozone depleting blends (eg R402A, R403B, R408A etc) without the need to change the existing lubricant or make any changes to the system other than adjustment to the. This compressor uses a mineral oil, while the R-410A compressor works with man-made oil. This unique refrigerant remains the most widely used gas in the acr industry today, with over an estimated 100,000 tonnes in use in Europe. It has a low ODP (Ozone Depletion Potential). 5°C to 11°C) increase in compressor discharge temperature is desirable, such as some ice machines and other self-contained systems. These new rules targeting the high GWP refrigerants will affect R404A, R507A and R422A (MO79), all of which were substitutes for R22 or R502 and all with GWPs of over 3,000. It is non toxic, pollution-free and non-corrosive, and features good oil solubility, small filling weight, high working efficiency, energy saving, and environmental protection. Maxi-Frig are refrigerants that were developed as an effective replacement for non-ozone-depleting substitutes for CFC-12, CHFC-22 and R502. Copeland's lubricant recommendation for use with R-402A/R-408A is a mixture of 50% mineral oil and 50% alkyl benzene Copeland approved polyol ester lubricants can also be used with R-402A/R-408A if the system is. 3 Alternatives for CFC and HCFC refrigerants (chlorine free HFC refrigerants) Fig. Duracool Refrigerants contain Duracool A/C Oil Chill™ a synthetic friction reducing additive. R502, R507A), which behave as single substance refrigerants with regard to evaporation and condensing processes, the phase change with zeotropic fluids occurs in a "gliding" form over a certain range of temperature. Mobil Zerice S Series Premium synthetic refrigeration compressor lubricants for ultralow temperature applications Features and Benefits Outstanding solubility with halocarbon refrigerants, helping avoid oil separation and congealing on the valve and heat-transfer surfaces of the refrigeration system. The solubility of HFC-134a in POE is less than the solubility of CFC-12 in naphthenic mineral oil. Use it with HFC leak detectors. Easy to view 4. Find refrigerant recovery systems here, including refrigerant recovery machines and accessories such as a pre-filter dryer and a level sensor float cable. 03 2300 r402b (hp81) r502 lm 0. Refrigerant R507 (R125, R143A)) It is very comparable in blend to R502 which has been in use for several decades. All are tested to meet or exceed AHRI-700 purity. This oil can be added through discharge outlet(s) connection. Unbeatable prices and exceptional customer service from WebstaurantStore. SYNTHETIC REFRIGERATION COMPRESSOR RAB-68 Summit RAB-68 refrigeration oil is alkylate based and formulated for use in reciprocating, rotary, and centrifugal refrigeration compressors using ammonia, R12, R22, R114 and R502. REFRIGERANT REFRIGERANT REPLACEMENT (ZERO ODP) LONG-TERM REPLACEMENT R13 OIL Mineral Alkylbenzene APPLICATION Ultra Low Temp Refrigeration CFC R503 OIL Mineral Alkylbenzene APPLICATION Ultra Low Temp Refrigeration CFC R22 OIL Mineral Alkylbenzene Polyol Ester APPLICATION Low Temp Refrig Med Temp Refrig Air Conditioning HCFC R438A ISCEON® M099. Car air conditioner refrigerant three-color charging hose. It is suitable for HCFC series refrigerant (R22,R502). R22 is the short name for the halocarbon compound CHClF2 (monochlorodifluoromethane), which is used as the refrigerant. CIMCO “C” Oil has a long history of excellent, trouble-free service in many types of equipment. Herbal Extracts & Biological Products. Mineral Oil (MO) Ammonia Oil; Polyalkylene Glycol Oil (PAG) Polyol Ester (POE) Alkylbenzene Oil (AB) Polyalphaolefin Oil (PAO) Vacuum Pump Oil; Chemicals for HVACR. Duracool A/C Oil Chill reduces compressor operating temperatures and improve thermal and chemical stability. The item "Refrigerant Vacuum Pump Gauge manifold Set Kit R12 R22 R502 R1270 R407F CARE 30″ is in sale since Monday, January 14, 2019. 502a operates at lower head pressures and offers improved cooling properties and performance verses R502. Veterinary Drugs. of the refrigerants R1234yf and R134a PAO Oil for refrigerant R134a, partly for refrigerant R1234yf and other refrigerants Can be used as an alternative to the various PAG oils that are offered for R134a (has the advantage of not being hygroscopic, i. Aupoko A/C AC Oil and Dye Injector, 2 OZ Hand Turn Screw-in Type Oil Fluorescent UV Dyes Refrigerant R410A, R134A, R22 and R12 Charger, with 1/4" SAE Connector and R134A Snap Quick Coupler. The high capacity of RS-52 at low temperatures is a prominent feature of this new refrigerant. 4 VALVE R134A R502 R22R12 Manifold Gauges A/C Tester Freon gas Service Diagnostic AC W/ 4 HOSES. Developed for use in low temperature refrigeration (the evaporator pressure stays out of vacuum down to -40°F). A wide variety of r404a refrigerant oil options are available to you, such as electron grade, reagent grade, and agriculture grade. For blend refrigerants, pressure-temperature data will include bubble and dew point data. RS-52 can also replace R22 in systems which are rated for R502. Meanwhile, it can keep liquidity at extreme low temperature. The final customer (the user) was paying (a lot). One Shot® (C) provides ample oil return in mineral oil-based systems without any significant engineering changes. York oils like (H oil,L oil Etc, Trane 025E oils, Emkarate oils & Gases like R22 Mafron India, R410 A ,R404A,407A. R407A, R407F, R448A and R449A are blend refrigerants. The word refrigerant typically refers to a liquid substance or mixture used in heat pumps or refrigeration cycles. The original refrigerants and the. REFRIGERANT REFRIGERANT REPLACEMENT (ZERO ODP) LONG-TERM REPLACEMENT R13 OIL Mineral Alkylbenzene APPLICATION Ultra Low Temp Refrigeration CFC R503 OIL Mineral Alkylbenzene APPLICATION Ultra Low Temp Refrigeration CFC R22 OIL Mineral Alkylbenzene Polyol Ester APPLICATION Low Temp Refrig Med Temp Refrig Air Conditioning HCFC R438A ISCEON® M099. It operates at lower head pressures and offers improved cooling properties and performance verses R134a. There's a simple rule in the industry that HFC-404A refrigerant needs to be used with POE oil. DURACOOL® Refrigerant will improve the performance and the life expectancy of refrigeration equipment and air-conditioning systems. Enviro-Safe Refrigerant is the refrigerant of the future. ceptable to use this compressor as a service replacement with R502. Instead of guessing I would like to just start over with a fresh charge of something. Refrigerant gas R507 for use in supermarket display case, ice machine, auto-refrigeration. This compressor uses a mineral oil, while the R-410A compressor works with man-made oil. Car air conditioner refrigerant three-color charging hose. ceptable to use this compressor as a service replacement with R502. com, A Leading Online Retailer!. In an automotive engine, motor oil stays in the crankcase where it belongs. Dupont Suva R123 Refrigerant Gas is an HFC retrofit refrigerant for R-12. Skip this step if the refrigerant you are adding contains oil. Definately R408a, it is very happy with mineral oil, however I would not mix it with R502!!!!! BTW, Whats the point of using a drop in refrigerant if you have to change to AB oil, it's not really a drop in then is it?. Tecumseh Hermetique Compressor, Hermetique Compressor, Reciprocating Compressor manufacturer / supplier in China, offering Tecumseh Compressor R502 Refrigerant (CAJ2428L), 3-50HP Original Bitzer Brand Semi-Hermetic Reciprocating Compressor for Refrigeration, Coldmach Outdoor Package Condensing Unit / Refrigeration Unit / Cdu and so on. View a vast selection of Refrigerant 502, all carefully selected. R-502 Other names and brand names: CFC-502, Freon-502 Genetron-502, Forane-502 Freon is a registered trade name for E. Browsing for r500 refrigerant for sale? The best online shopping experience is guaranteed! 335 r500 refrigerant products from 111 r500 refrigerant suppliers on Alibaba. Compatible with mineral, ester or pag oils. Suitable for test R410/134a R502 R12 R22 refrigerant. Unlike such oils, refrigeration oils are expected to give trouble-free service. 7 / Piece, Guangdong, China, Airmender, S-5202/4005. Meanwhile, it can keep liquidity at extreme low temperature. It is most suitable for HCFC refrigerants (R22. Refrigerant Gauge Manifold Set for R12,R22,R134A,R410A Single Gauge Valve Quick Detail. refrigeration; chillers; reefer. This technical topic guides you through the process, giving you the details on:. 2 Oil and refrigerant charges 398 13. Shop for Refrigeration Test Equipment and other test & measurement instruments at Instrumart. - The initial high velocity reduction of the oil vapour/liquid results. An energy-efficient, ultra-low GWP refrigerant replacement for R134A in medium Temperature applications like heat pumps, air-cooled and water-cooled chillers, district heating and cooling systems, vending machines, plug-ins and domestic refrigeration, beverage dispensers, CO2 cascade systems and transport refrigeration. Our refrigerants are completely compatible with the synthetic oil used with HFC R134a and the organic oils used with CFC R12, HCFC R22, and CFC R502 systems. System was not labeled with the refrigerant that was in it. Modular Products Inc. A refrigerant is a substance or mixture, usually a fluid, used in a heat pump and refrigeration cycle. miscibility with the refrigerants R22 and R502, the refrigeration oils of the RENISO MS series are especially recommended for these HCFC refrigerants and as well for chlorine-containing “drop in” refrigerants, e. Has Reading of Three color-coded service hose Freon Charging hose burst, max W. Another problem with commercial LPG is that the composition of. Since a drop-in replacement is the focus of the present study, the conventional mineral oil used with R502 is used for all. eral oil lubricant from the system before the refrigerant is changed. Refrigerant R12 or Freon 12 is the most widely used of all the refrigerants for different refrigeration and air conditioning applications. Refrigeration Lubricants SUNISO SL-32: SUNISO SL grades are synthetic ester lubricants, formulated using select polyolester base stocks and additives providing outstanding lubricity, stability and corrosion protection. For removal of the refrigerant it is necessary to create 3035 кPа vacuum. 4 Alternatives for CFC and HCFC refrigerants (halogen free refrigerants) Explanation of Fig. R402A (HP80) R402A, also known as HP80, is an HCFC blend with a small amount of hydrocarbon included to improve mineral oil compatibility. Use refrigerant grade products only. All air conditioners use an oil to keep the compressor lubricated during operation. 4 VALVE R134A R502 R22R12 Manifold Gauges A/C Tester Freon gas Service Diagnostic AC W/ 4 HOSES. It is non toxic, pollution-free and non-corrosive, and features good oil solubility, small filling weight, high working efficiency, energy saving, and environmental protection. Aupoko A/C AC Oil and Dye Injector, 2 OZ Hand Turn Screw-in Type Oil Fluorescent UV Dyes Refrigerant R410A, R134A, R22 and R12 Charger, with 1/4" SAE Connector and R134A Snap Quick Coupler. Low- and medium-temperature retrofits. Rugged open drive compressor provides years of reliable service, even on refrigerants heavily contaminated with oil, air, moisture, & acids. Your recovery/recycling machine has R502 refrigerant in it. R404A has been developed as an alternative to R502 for refrigerators and freezers. Refrigerant gas R507 for use in supermarket display case, ice machine, auto-refrigeration. Health and Safety was not the issue that it is now. 05 1500 r409a (fx56) r12 lm hfc / hfo 0 1430 r134a r12 mh new and retrofit poe 0 0 3922 r404a r502 lm 0 3980 r507 r502 lm 0 2107 r407a r22/r502 lm 0 1770 r407c r22 mh 1824 r407f r22/r404a lm. which color cylinder designates r-134a r502, and r500. Refrigerant Supply is the right place to come to if you would like one company that will actively buy refrigerants as well as sell refrigerant to its clients. A/C System Sealer (Industrial) Large A/C (R22, R502) Leak Repair - 1 - 4 oz. It is especially formulated for severe service under conditions that are beyond the capabilities of conventional mineral oils. R407A, R407F, R448A and R449A are blend refrigerants. Buy Ktaxon 3CFM HVAC Vacuum Pump & Manifold Gauge Kit for R134A R502 Refrigerant, 1/4 HP Portable Electric Rotary Vane A/C 1 Stage Air Conditioner Deep Small Refrigerant Evacuation/Suction Pump & Gauge at Walmart. Has Reading of Three color-coded service hose Freon Charging hose burst, max W. R422B is an HFC refrigerant, which means that it is made of hydrogen, fluorine, and carbon. The name of the gas are usually labelled on the cylinders as an added aid so that we will not make any mistakes in recognizing them. Highlighting our full group of r134a refrigerant gas available on sale online. Refrigerant Reference Guide 55 5th Edition 2010 R-500 and R-502 Technical Guidelines R-500 CFC 99. R22 Oil comes in 3 ounce can. York oils like (H oil,L oil Etc, Trane 025E oils, Emkarate oils & Gases like R22 Mafron India, R410 A ,R404A,407A. Posts about refrigeration compressor written by MPS. ceptable to use this compressor as a service replacement with R502. , Ltd is a professional production and processing refrigeration equipment and accessories manufacturers. Combines capabilities of Evac Commercial & Lovac systems to offer great recovery rates on R11, R12, R22, R113, R123, R134a, R404, R500, R502, R410a & other high pressure refrigerants or blends. Design of anti-collision machine, it is safety and environmental. The blend is designed to be a retrofit replacement for R502 in medium temperature refrigeration applications. Yet there are reports of HCFC-22 refrigeration systems being converted to R-404A, but without changing out the mineral oil to a POE. For more than 80 years, DAIKIN has been a leading producer of fluorine refrigerants. Pressure scale 0-500psi, for R410A, R134A,R22,R12,R502 refrigerants. Tecumseh Hermetique Compressor, Hermetique Compressor, Reciprocating Compressor manufacturer / supplier in China, offering Tecumseh Compressor R502 Refrigerant (CAJ2428L), 3-50HP Original Bitzer Brand Semi-Hermetic Reciprocating Compressor for Refrigeration, Coldmach Outdoor Package Condensing Unit / Refrigeration Unit / Cdu and so on. Refrigerant R22 has approximately 55% higher refrigerating capacity and pressure levels than R12**. One Shot® (C) is in use in thousands of installations throughout the world. Catalyst #1: removes the oil fouling and allows maximum heat exchange rate by reducing the surface tension of compressor oil molecules. lower oil consumption and hence the need for less makeup oil. Oil return becomes critical when this degree of superheat occurs and the oil temperature is below 20ºF and 40ºF. 4 Alternatives for CFC and HCFC refrigerants (halogen free refrigerants) Explanation of Fig. Electronic oil-pressure switch. R-502 Other names and brand names: CFC-502, Freon-502 Genetron-502, Forane-502 Freon is a registered trade name for E. Unbeatable prices and exceptional customer service from WebstaurantStore. Top it off repeatedly. The word refrigerant typically refers to a liquid substance or mixture used in heat pumps or refrigeration cycles. R422A (FREON™ MO79) R422A is a HFC refrigerant blend of R125, R134a and R600a. I beleive Copeland states that the oil level in the compressor should be at the 3/4 mark of the sight glass. With R-410A, the same unit will operate under the same conditions with a suction pressure of 118 psi and a discharge pressure of 400 psi, as shown in Figure 1 on the next page. Although propane will improve oil circulation, it is still recommended that some mineral oil be replaced with alkylbenzene. It's the key to absorbing and removing heat from a space. R12 R22 R134a R502 Manifold Gauge Set HVAC A/C Refrigeration Charging Service US New listing Polyol Ester POE Refrigeration Oil Lubricant Emkarate RL 32. Refrigerant R507 (R125, R143A)) It is very comparable in blend to R502 which has been in use for several decades. Oil is dissolved into the refrigerant and is carried around the system. Instead of guessing I would like to just start over with a fresh charge of something. R22 Oil comes in 3 ounce can. R402A (HP80) R402A, also known as HP80, is an HCFC blend with a small amount of hydrocarbon included to improve mineral oil compatibility. This paper concentrates on the use of R417A (ISCEON ® 59) in existing equipment designed for use with R22 use traditional mineral oil or alkyl benzene lubricants. As the industry faces the regulations to phase out Ozone Depleting Substances, known as the Montreal Protocol, DAIKIN has been at the forefront of the drive to provide environmental friendly refrigerants. ceptable to use this compressor as a service replacement with R502. better oil-return performance at low temperarures than the current mineral oil and R502 combination. Evacuate system and check for leaks. Cavitation damage. 0 visualized in a similar flow through the glass tube, was not sufficient to change the single-phase flow characteristics. Best for low temp R-12and R-500 retroit applications. for the conversion to polyolester oil. The following is a list of refrigerants with their Type/Prefix, ASHRAE designated numbers, IUPAC chemical name, molecular formula, CAS registry number / Blend Name, Atmospheric Lifetime in years, Semi-Empirical Ozone depletion potential, net Global warming potential over a 100-year time horizon, Occupational exposure limit/Permissible exposure. RAB-68 synthetic refrigeration compressor oil is recommended for reciprocating, rotary, and centrifugal refrigeration compressors using ammonia, R12, R22, R114, and R502 as the refrigerant. charging with refrigerant until. The high capacity of RS-52 at low temperatures is a prominent feature of this new refrigerant. * R12, R22 & R502 Refrigerant Oil CAUTION Minor variations in typical physical properties may occur from normal manufacturing processes. Although propane will improve oil circulation, it is still recommended that some mineral oil be replaced with alkylbenzene. Heavy-duty fi lter can handle up to 300 lbs. Combines capabilities of Evac Commercial & Lovac systems to offer great recovery rates on R11, R12, R22, R113, R123, R134a, R404, R500, R502, R410a & other high pressure refrigerants or blends. The schematic and pressure–enthalpy (P–h) diagram of this cycle are shown in Figure 1. Selecting a refrigeration lubricant When it comes to choosing the right refrigeration lubricant for industrial systems, there’s plenty to keep in mind. Refrigeration compressors and air conditioning compressors provide air conditioning, heat pumping, and refrigeration for large-scale facilities and equipment. Product Description. Freon™ HP81 is an HCFC retrofit refrigerant for R-502 in limited applications where a 10°F to 20°F (5. R-502 offers lower discharge temperature and improved capacity compared to R-22. CFC and HCFC refrigerants (Freon, Arcton, etc. All of our General Refrigeration Lubricants are 100% OEM compatible and are formulated to achieve the best results. 5 Isobutane (R600a) was first used as a refrigerant for small systems in the 1920s but, as with other flammable refrigerants (except ammonia), it quickly fell out of use when chloro-fluorocarbon (CFC) refrigerants were. R12 is a highly versatile refrigerant that can be used in wide range of the operating conditions without getting disintegrated. SRO 500 Synthetic Refrigerant Oil is a fully synthetic industrial lubricant developed specifically for auto air conditioning compressors. Refrigerant Charging Hose with Ball Valves HVAC 1/4'' SAE R410A 800 PSI Fit for R134A R12 R22 R502 R404 Coolant Adding and Air Condition Maintenance 3-Color 3 Pcs $47. The schematic and pressure-enthalpy (P-h) diagram of this cycle are shown in Figure 1. 3" color graphical display. It is suited for R11, R12, R22, R113, R114, R502, R600a and so on. Best drop-in solution to replace R502 is DuPont Isceon 79. Another major difference between R-22 and R-410A compressors is that the R-22 refrigerant is being phased out. CIMCO "C" Oil A premium quality, napthenic based, multi-purpose oil designed for use in most R717, R12, R22 and R502 refrigeration compressors. The refrigerant R502: Used in the refrigeration industry in general is also banned in Europe because paise pollutant ozone layer The refrigerant R134a is the substitute of R12 refrigerant gas not containing a single chlorine atom. Refrigerant Changeover Guidelines CFC R-502 to HFC R-404A/R-507 Leading the Industry with Environmentally Responsible Refrigerant Solutions. Heat resistance and abrasion resistance of the pump is greater. This instruction is not intended to teach piping practices or be a substitute for these proven methods. Typically, the refrigerant, when used in a freezer, is converted from liquid to gas and then back again. 0 visualized in a similar flow through the glass tube, was not sufficient to change the single-phase flow characteristics. was founded in 1962 by the late Israel Dayan, and deals in import , export, marketing and distribution of refrigeration and air-conditioning equipment. Car air conditioner refrigerant three-color charging hose. lower oil consumption and hence the need for less makeup oil. Refrigerant R502 has been successfully used with naphthenic mineral oil in commercial refrigeration systems. R402A (HP80) R402A, also known as HP80, is an HCFC blend with a small amount of hydrocarbon included to improve mineral oil compatibility. Suniso SL oils are miscible with HFC refrigerants at extremely low temperatures. In many countries new air conditioning and refrigeration manufacturing is being geared towards hydrocarbon technologies because of their energy savings and minimal effect on our environment. Are Enviro-Safe™ Refrigerants corrosive to air conditioning systems? Can I mix Enviro-Safe™ Refrigerant with other refrigerants? What is the difference between Enviro-Safe™ Refrigerant and HFC-134a? How do I know how much refrigerant I need in my vehicle? Is Enviro-Safe™ Refrigerant compatible with other refrigerants?. R22 is the short name for the halocarbon compound CHClF2 (monochlorodifluoromethane), which is used as the refrigerant. It provides very similar performance to R-502 over the entire operating range. AR2700 SERIES REFRIGERANT RECOVERY/ RECYCLING SYSTEM FEATURES AND BENEFITS: • Semi-automatic, easy-to-use Recovery, Recycle, Evacuate and Recharge machine • Utilizes manual ball valves in place of solenoids, making the AR2700 impervious to contamination and sealants • Simple operation for oil waste and air purge. miscibility with the refrigerants R22 and R502, the refrigeration oils of the RENISO MS series are especially recommended for these HCFC refrigerants and as well for chlorine-containing "drop in" refrigerants, e. PAO-Oil 68 is suitable for all types of refrigerant and does not accumulate in evaporators and condensers, which often results in a reduction of cooling performance when other oils are used. Our refrigerants are completely compatible with the synthetic oil used with HFC R134a and the organic oils used with CFC R12, HCFC R22, and CFC R502 systems. These lubricants are miscible in alternative refrigerants such as R-134a at extre¬mely low temperatures. Learn about the properties of this formula. Heat resistance and abrasion resistance of the pump is greater. Airmender brand liquid refrigeration oil separator S-5202/4005, US $ 10 - 17. Refrigerant Charging Hose with Ball Valves HVAC 1/4'' SAE R410A 800 PSI Fit for R134A R12 R22 R502 R404 Coolant Adding and Air Condition Maintenance 3-Color 3 Pcs $47. 5°C to 11°C) increase in compressor discharge temperature is desirable, such as some ice machines and other self-contained systems. As a control, some samples were exposed to the original refrigerant/mineral oil for a total of 1000 hours. Refrigerant Products And Packing. PAO-Oil 68 is suitable for all types of refrigerant and does not accumulate in evaporators and condensers, which often results in a reduction of cooling performance when other oils are used. RS-50 (R442a) Refrigerant, R404a & R507 Replacement ` RS-50 (R442a) is a very low GWP (less than one half) high efficiency drop-in replacement for R404a and R507 refrigerants. Rugged open drive compressor provides years of reliable service, even on refrigerants heavily contaminated with oil, air, moisture, & acids. Industrial refrigerants are found in nearly every cooling device, from air conditioners to refrigerators to freezers. All are tested to meet or exceed AHRI-700 purity. Add to Cart RS-52 Refrigerant, R502 Replacement `. Electronic oil-pressure switch. For additional information, visit alfacantor. White Paper: Revisiting Flammable Refrigerants a replacement for ammonia refrigerant in the 1920s. It is the world leading refrigeration oil. The properties of the oil selected must be suitable for this purpose. 1 and 2 show the viscosity changes caused by the solubility between POE and the refrigerant gas. An azeotropic refrigerant is a mixture of two or more components that boil at the same temperature. The solubility of HFC-134a in POE is less than the solubility of CFC-12 in naphthenic mineral oil. Refrigerant gas R507. Rugged open drive compressor provides years of reliable service, even on refrigerants heavily contaminated with oil, air, moisture, & acids. In most cycles it undergoes phase transitions from a liquid to a gas and back again. It has a low ODP (Ozone Depletion Potential). 1 Compressors 403 13. Evacuate system and check for leaks. Moisture tolerant. miscibility with the refrigerants R22 and R502, the refrigeration oils of the RENISO MS series are especially recommended for these HCFC refrigerants and as well for chlorine-containing “drop in” refrigerants, e. R502 from Zambia - Free to use unique search engine of reliable, genuine and verified companies, suppliers, exporters, sellers, manufacturers, factories, traders, tradeleads of products and services from all over the world. Comparative parameters of R502 and R408A refrigerants. R404A is a HFC blend, used as a replacement for R502 and R22 in low and medium temperature refrigeration applications. ceptable to use this compressor as a service replacement with R502. elevated temperature to the original refrigerant and mineral oil for 500 hours, followed by exposure to the alternative refrigerant and lubricant for 500 hours. And vanes are aetonautical materials. Refrigerant Liquid Pump The Refrigerant Liquid Pump is a commercial/industrial grade pump used to transfer all Class I, II, III and IV refrigerant at rates up to 20GPM. Yet there are reports of HCFC-22 refrigeration systems being converted to R-404A, but without changing out the mineral oil to a POE. Best drop-in solution to replace R502 is DuPont Isceon 79. It is suitable for HCFC series refrigerant (R22,R502). 502a operates at lower head pressures and offers improved cooling properties and performance verses R502. 5 Isobutane (R600a) was first used as a refrigerant for small systems in the 1920s but, as with other flammable refrigerants (except ammonia), it quickly fell out of use when chloro-fluorocarbon (CFC) refrigerants were. Production of the R-500 refrigerant halted on January 1, 2006 because of its environmentally harmful chemical makeup. OIL SEPARATOR INSTALLATION INSTRUCTIONS Proper piping practices must be followed in all installations. XXVIII, No. Mobil-branded Refrigeration Lubricant Selection Guide for Industrial Systems Listed here are some of the high-performance Mobil Industrial Lubricants for refrigeration applications, each one formulated to offer outstanding equipment protection and extended oil life. These liquids are used in vapor compression refrigeration systems to transfer heat from one area to another. DuPont Refrigerants without an oil change DuPont™ ISCEON® 9 Series refrigerants are Mineral Oil compatible and typically do not require an oil change except ISCEON® 39TC® which requires only one oil change to POE. For blend refrigerants, pressure-temperature data will include bubble and dew point data. When upgrading a system from a CFC refrigerant such as R502 to a HFC refrigerant such as R507, the POE oil will readily remove any trace amounts of the mineral oil they are replacing. Many working fluids have been used for such purposes. Opteon™ refrigerants for air conditioning, refrigeration, and heat pump applications have the optimal balance of performance, environmental sustainability, safety, and cost. A/C Diagnostic Manifold Gauge Set Charging Refrigeration HVAC R12 R22 R134A R502.